Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.221
Filtrar
1.
J Oral Implantol ; 50(1): 18-23, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38579115

RESUMEN

Bone augmentation is often required before the installation of dental implants. Here, we report a case for a patient who previously received bone augmentation at the upper right jaw using a xenogenic graft, followed by successful implant installation. Seven years later, the patient presented with mucosal fenestration with bone exposure at the area and gave a history of a recent diagnosis of cutaneous lichen planus. Several attempts were made to manage the situation, and finally, we resorted to connective tissue graft placement at the site. A piece of bone was sent for histologic evaluation, where the results indicated the presence of un-resorbed graft material surrounded by inflammatory cells, with no evidence of bone formation in the area. The case presents histologic evidence for the lack of new bone formation using xenograft over the evaluation period. The case also shows lichen planus, a possible cause for oral complication for patients undergoing augmentation and implant installation.


Asunto(s)
Aumento de la Cresta Alveolar , Implantes Dentales , Humanos , Implantación Dental Endoósea/métodos , Xenoinjertos , Aumento de la Cresta Alveolar/métodos , Osteogénesis , Trasplante Óseo/métodos
2.
J Oral Implantol ; 50(1): 9-17, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38579116

RESUMEN

The goal of this clinical report was to present an alternative to traditional flat bone reduction guides, using a custom-designed 3-dimensional (3D)-printed guide according to the future gingival margin of the planned dentition. A 61-year-old woman with concerns regarding her smile appearance was presented. The initial examination revealed excessive gingival show accompanied by excessive overjet. The dentition was in a failing situation. The proposed treatment plan, relying on the sufficient amount of bone and keratinized tissue, consisted of recontouring of the alveolar ridge and gingiva and placement of 6 implants and an FP-1 prosthesis after extraction of all remaining maxillary teeth. Digital smile design was completed, and a fully digitally guided surgery was planned. This consisted of using 3 surgical guides, starting with the fixation pin guide, continuing with the scalloped hard- and soft-tissue reduction guide, and finally the implant placement template. Following the surgery, the patient received a temporary restoration, and on the 4-month follow-up, a new polymethyl meta-acrylate temporary prosthesis was delivered. The patient's 7-month follow-up is presented in the article. The report of this triple-template guided surgery indicated that digital 3D planning is a considerably predictable tool to properly establish and evaluate future occlusal plane, smile line, and lip support. Scalloped guides seem to be an excellent alternative to conventional bone reduction guides since they require less bone removal and improve patient comfort during surgery.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Humanos , Femenino , Persona de Mediana Edad , Implantación Dental Endoósea/métodos , Proceso Alveolar , Encía/cirugía , Implantación de Prótesis , Prótesis Dental de Soporte Implantado
3.
Int J Oral Maxillofac Implants ; 39(2): 206-223, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38657215

RESUMEN

PURPOSE: To analyze the available evidence and assess the effect of different implant coatings on healing outcomes. MATERIALS AND METHODS: Using the PICOS strategy, a structured question was formed. A protocol was agreed upon and registered with PROSPERO (no. CRD42022321926). The MEDLINE, Embase, Cochrane Database of Systematic Reviews, Scopus, Web of Science, Pubmed, and ScienceDirect databases were searched using a structured strategy. Study selection was independently carried out in duplicate, first by title and abstract, then by full-text assessment. Quality and risk of bias were independently assessed in duplicate using AMSTAR 2 and ROBIS. Data extraction was independently undertaken in duplicate using a predefined extraction form. RESULTS: The search yielded 11 systematic reviews for inclusion. The most commonly assessed coatings were based on calcium phosphate-including hydroxyapatite (HA), brushite, and bioabsorbable nano-HA-followed by bisphosphonate, then bioactive glass coatings. Included reviews most frequently assessed marginal bone loss (MBL), bone-to-implant contact (BIC), and survival/success rates. There was considerable heterogeneity and small sample sizes. The quality assessment suggested low confidence in the reviews and high risk of bias. CONCLUSIONS: The included reviews provide weak evidence that implant coatings improve osseointegration and reduce MBL following implant placement. There was weak evidence for progressive complications for calcium phosphate coatings. Further research and long-term multicenter controlled clinical trials with improved standardization and control of bias are required to better understand the effects of coating implants.


Asunto(s)
Materiales Biocompatibles Revestidos , Implantes Dentales , Humanos , Materiales Biocompatibles Revestidos/química , Cicatrización de Heridas , Implantación Dental Endoósea/métodos , Fosfatos de Calcio , Durapatita , Oseointegración/fisiología
4.
Int J Oral Maxillofac Implants ; 39(2): 243-253, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38657217

RESUMEN

PURPOSE: To validate an innovative 3D volumetric method of evaluating tissue changes proposed by Lee et al in 2020 by comparing the results of this method-in which the scanned peri-implant surfaces were transformed, visualized, and analyzed as 3D objects-to the results reported by an existing method based on calculation of the mean distance between measured surfaces. The null hypothesis was that there was no statistically significant difference between the two methods. Additionally, the present study evaluated peri-implant tissue changes 5 years after single implant placement in the esthetic zone. MATERIALS AND METHODS: Both methods were applied to 11 oral implant site casts (6 maxillary central incisor sites, 5 maxillary lateral incisor sites) taken from 11 patients at crown placement and at follow-up examinations 5 years later. The methods are based on digital workflows in which the reference and 5-year casts are scanned and the resulting STL files are superimposed and analyzed for three regions of interest (mesial papilla, central area, and distal papilla). The volumetric changes reported by the Lee et al method and the mean distance method were calculated and compared using the Spearman rank correlation coefficient (P < .01) and the Wilcoxon signed-rank test (P < .05). RESULTS: The correlation between the two sets of measurements was very high (Spearman rank correlation coefficient = 0.885). The new volumetric method indicated a mean volume loss of 2.82 mm3 (SD: 5.06), while the method based on the measurement of mean distance showed a mean volume loss of 2.92 mm3 (SD: 4.43; Wilcoxon signed-rank test result: P = .77). No statistically significant difference was found. The two methods gave equivalent results, and the null hypothesis was accepted. CONCLUSIONS: The new volumetric method was validated and can be considered a trustworthy tool.


Asunto(s)
Implantes Dentales de Diente Único , Imagenología Tridimensional , Humanos , Imagenología Tridimensional/métodos , Maxilar/cirugía , Maxilar/anatomía & histología , Femenino , Implantación Dental Endoósea/métodos , Modelos Dentales , Coronas , Masculino , Adulto , Incisivo/anatomía & histología
5.
Int J Oral Maxillofac Implants ; 39(2): 263-270, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38657218

RESUMEN

PURPOSE: To describe the use of digital technology to surgically guide the shell technique using allogenic cortical plates for a fully guided bone augmentation procedure. MATERIALS AND METHODS: A total of 10 patients who required bone augmentation for implant placement were included in this study. Allogenic cortical plates were planned using CAD/CAM to have identical thickness to the original cortical plates, then were digitally positioned and shaped to outline the bone defect according to the existing anatomical details. A cutting pattern and a surgical template were manufactured according to the digitally preplanned bone graft and the intraoral setting. RESULTS: A total of 12 horizontal bone grafting procedures were performed using the shell technique with allogenic cortical plates. All grafting procedures were deemed successful and allowed for ideal 3D implant positioning. Of the 12 bone grafting procedures, which used a surgical template to position the cortical plate, 3 required an adjustment to reposition the plate to a more ideal position. CONCLUSIONS: Digital technology was used to create a surgical template to guide the shell bone grafting technique with allogenic cortical plates. All surgical templates offered a fixed support to hold the cortical allogenic plate in the preplanned position, offering a predictable, simplified, and accurate guided bone grafting procedure. Further studies on a larger population of patients are necessary to assess those results and to verify the treatment approach described in this study.


Asunto(s)
Aumento de la Cresta Alveolar , Placas Óseas , Trasplante Óseo , Diseño Asistido por Computadora , Humanos , Estudios Prospectivos , Masculino , Femenino , Aumento de la Cresta Alveolar/métodos , Persona de Mediana Edad , Trasplante Óseo/métodos , Adulto , Implantación Dental Endoósea/métodos , Resultado del Tratamiento , Cirugía Asistida por Computador/métodos , Trasplante Homólogo , Anciano , Tomografía Computarizada de Haz Cónico
6.
Int J Oral Maxillofac Implants ; 39(2): 271-277, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38657219

RESUMEN

PURPOSE: To investigate the relationship between the structural parameters of trabecular bone obtained from CBCT imaging and the primary stability of dental implants. MATERIALS AND METHODS: Sixty patients underwent implant placement followed by primary stability evaluation via measurement of the insertion torque (IT) and the implant stability quotient (ISQ). Gray values (GV) and the fractal dimension (FD) were also measured using pretreatment CBCT images. RESULTS: FD values showed a positive and significant relationship with ISQ and IT values (P = .017 and P = .004, respectively). Additionally, there was a positive and significant correlation between GV and IT (P = .004) as well as between GV and ISQ (P = .010). FD and GV showed a considerable difference between the maxillary and mandibular jaws and were higher in the mandible. Only FD was significantly different between men and women and was higher in men. In the two age groups (older and younger than 45 years), only GV was considerably higher in people older than 45 (P < .05). CONCLUSIONS: Both fractal dimension and gray values obtained from CBCT are efficient methods for predicting the primary stability of the implant due to their relationship with ISQ and IT values.


Asunto(s)
Hueso Esponjoso , Tomografía Computarizada de Haz Cónico , Implantes Dentales , Fractales , Humanos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Hueso Esponjoso/diagnóstico por imagen , Implantación Dental Endoósea/métodos , Torque , Anciano , Retención de Prótesis Dentales , Mandíbula/diagnóstico por imagen
7.
Head Face Med ; 20(1): 24, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627712

RESUMEN

OBJECTIVES: A randomized controlled clinical trial of dental implants was conducted to compare the clinical properties of a novel electrochemically deposited calcium phosphate coating to those of a common marketed surface treatment. MATERIAL AND METHODS: Forty implants of the same brand and type were placed in 20 fully edentulous participants requiring mandibular implantation. The two study groups were defined by the surface treatment of the implants. 20 implants in the control group were coated via a commercial electrochemical surface treatment that forms a mixture of brushite and hydroxyapatite, while the remaining 20 in the test group were coated with a novel electrochemical Smart Bioactive Trabecular Coating (SBTC®). A split-mouth design was employed, with each participants receiving one control implant in one mandibular side and a test implant in the other. To mitigate potential operator-handedness bias, control and test implants were randomly assigned to mandibular sides. All cases underwent digital planning, implant placement with a static surgical guide, and participants received locator-anchored full-arch dentures. The primary outcome was implant stability (measured using Osstell ISQ) assessed at insertion, loading, and then 3 months, 9 months, and 2 years post-insertion. The secondary outcome was bone level change (in millimeters) over the 2-year observation period. Oral health-related quality of life (OHRQL) was monitored using the OHIP-14 questionnaire. Complications and adverse events were recorded. RESULTS: Successful osseointegration and implant stability were achieved in all cases, allowing loading. ISQ values steadily increased throughout the observation period. While no significant differences were observed between the SBTC® and control coatings, the test group exhibited a higher ISQ gain. Bone resorption was somewhat lower in the SBTC® but not significantly so. Patients' OHRQL significantly improved after denture delivery and remained stable throughout the follow-up. No complications or adverse events were observed. CONCLUSIONS: Based on the study results, we conclude that the new surface treatment is a safe alternative to the widely used control surface, demonstrating similar osseointegrative properties and time-dependent bone level changes. Further research may explore the broader implications of these findings. TRIAL REGISTRATION: The study is registered on clinicaltrials.gov under the identifier ID: NCT06034171.


Asunto(s)
Implantes Dentales , Boca Edéntula , Humanos , Implantación Dental Endoósea/métodos , Calidad de Vida , Oseointegración , Resultado del Tratamiento , Prótesis Dental de Soporte Implantado/métodos , Diseño de Prótesis Dental
8.
Shanghai Kou Qiang Yi Xue ; 33(1): 64-70, 2024 Feb.
Artículo en Chino | MEDLINE | ID: mdl-38583027

RESUMEN

PURPOSE: To analyze the bone remodeling around the implant 10 years after disk-up sinus reamer(DSR)-based internal sinus floor elevation with implantation and to investigate the influence of different factors on implant retention. METHODS: The clinical and imaging data of patients undergoing DSR-based sinus floor elevation with simultaneous implantation were collected from the Department of Dental Implantology, Affiliated Hospital of Qingdao University from January 2008 to December 2011. Panoramic film and CBCT were used to measure the changes of bone mass around implant in different periods. Kaplan-Meier and Log-rank tests were used to analyze the effects of different factors on implant retention with SPSS 26.0 software package. RESULTS: The study included 98 patients with a total of 128 implants. During the follow-up of 0-168 months, 7 implants failed, and the remaining formed good osseointegration and functioned, with a 10-year cumulative retention rate of 94.53%. The height of bone formation was (0.29±0.15) mm at the top and (2.74±0.66) mm in the sinus of 75 implant sites with complete imaging data obtained ten years after surgery. Kaplan-Meier and Log-rank tests showed that 8 factors including initial bone height, elevated bone height, mucosal perforation, implant length, implant torsion, diabetes, smoking and periodontitis had significant effects on implant retention. CONCLUSIONS: The DSR-based internal sinus floor elevation with implantation is a reliable and stable bone augmentation operation for vertical bone defect in maxillary posterior region, with a 10-year cumulative retention rate of no less than 94%. Initial bone height, elevated bone height, mucosal perforation, implant length, implant torsion, diabetes, smoking and periodontitis are the important factors affecting the long-term retention rate of implants.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Elevación del Piso del Seno Maxilar , Humanos , Implantación Dental Endoósea/métodos , Diabetes Mellitus/cirugía , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Seno Maxilar/diagnóstico por imagen , Seno Maxilar/cirugía , Periodontitis , Resultado del Tratamiento
9.
J Oral Implantol ; 50(1): 24-30, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38579113

RESUMEN

Alveolar bone quality at the implantation site affects the initial stability of dental implant treatment. However, the relationship between bone quality and osseointegration has yet to be evaluated. Herein, we aimed to investigate the effect of bone quality on dental implant stability in osseointegration formation changes. Patients underwent computed tomography imaging before dental implantation at the posterior. Hounsfield units were measured at the platform, middle, and tip sites. Implant stability was measured using resonance frequency analysis immediately and at 3 months postoperatively, in which the difference in implant stability quotients (ISQ) was defined as the change between primary and secondary fixation. In multiple regression analysis, the dependent variable was the change between the immediate and secondary fixations. We included 81 implants that conformed to the criteria. Primary fixation yielded the following results: R2 = 0.117, F = 2.529, and P = .047. The difference between the maxilla and mandible of the implantation site (P = .02) and the platform-site Hounsfield units (P = .019) were identified as significant factors. The following results were obtained regarding the change between the immediate and secondary fixation: R2 = 0.714, F = 40.964, and P < .001. The difference between diameter (P = .008) and the immediate ISQ (P < .001) were identified as significant factors. Overall, the bone quality of the implantation site affected initial fixation; however, it had limited effect on secondary fixation. Our findings clarified the period where bone quality affects dental implant treatment and is expected to advance dental implant treatment.


Asunto(s)
Implantes Dentales , Humanos , Implantación Dental Endoósea/métodos , Densidad Ósea , Oseointegración , Tomografía Computarizada por Rayos X , Diseño de Prótesis Dental , Retención de Prótesis Dentales , Maxilar/diagnóstico por imagen , Maxilar/cirugía
10.
BMC Oral Health ; 24(1): 431, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589825

RESUMEN

OBJECTIVE: This study was designed to estimate the effect of sticky bone combined with concentrated growth factor (CGF) on anterior alveolar horizontal augmentation during implantation. METHODS: Twenty-eight patients were randomly assigned to either the test group (Group 1, n = 14) or the control group (Group 2, n = 14). Patients in Group 1 and Group 2 underwent GBR using sticky bone combined with CGF and bone powders mixed with saline, respectively. On postoperative Day 7, the patients completed the visual analogue scale (VAS). Three-dimensional models of maxillary alveolar bone were reconstructed from CBCT data at different periods, and the bone volume conversion rate was calculated with the assistance of a measurement marker guide. Labial bone thickness before and after trauma closure and bone density at six months postoperatively were also measured. RESULTS: The mean bone volume conversion rate for Group 1 (72.09 ± 12.18%) was greater than that for Group 2 (57.47 ± 9.62%, P = 0.002). The VAS score was lower for Group 1 than for Group 2 (P = 0.032). At six months postoperatively, greater bone density was found in patients in Group 1 than in those in Group 2, although the difference was not statistically significant (P > 0.05). The change in the thickness of the labial bone graft material in Group 1 was smaller than that in Group 2 (P = 0.025). CONCLUSION: Sticky bone combined with CGF was able to achieve better bone augmentation than conventional GBR. With excellent mechanical properties and the capacity to release growth factors, sticky bone is an ideal material for bone grafting. TRIAL REGISTRATION: The study was registered at the Chinese Clinical Trial Registry on 10/04/2022 (Identification number: ChiCTR2200058500).


Asunto(s)
Aumento de la Cresta Alveolar , Implantación Dental Endoósea , Humanos , Implantación Dental Endoósea/métodos , Aumento de la Cresta Alveolar/métodos , Trasplante Óseo , Maxilar/cirugía , Péptidos y Proteínas de Señalización Intercelular
11.
Gen Dent ; 72(3): 61-66, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38640008

RESUMEN

In addition to the proper selection of techniques, appropriate treatment sequencing and prioritization are prerequisites for successful periodontal and implant procedures. The aim of this study was to provide evidence-based time frames for various procedures pertaining to periodontal and implant treatment. A literature review was conducted to collect data on tissue healing; in areas in which data were lacking, the viewpoints of experienced clinicians were solicited to establish a consensus. This review reports recommended time frames for the healing processes associated with surgical crown-lengthening procedures (both functional and esthetic), fresh socket management, alveolar ridge management, soft tissue management, sinus floor augmentation, implant loading, and peri-implant defect management.


Asunto(s)
Aumento de la Cresta Alveolar , Implantes Dentales , Elevación del Piso del Seno Maxilar , Humanos , Aumento de la Cresta Alveolar/métodos , Implantación Dental Endoósea/métodos , Administración del Tiempo
12.
Compend Contin Educ Dent ; 45(3): 147-150, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38460139

RESUMEN

The lateralization of the inferior alveolar nerve, or LIAN procedure, may be a surgical consideration for implant-prosthetic rehabilitation in the edentulous mandibular posterior region. This technique can be advantageous in that it does not require a donor site and allows for the immediate placement of an implant, potentially leading to reduced morbidity, healing time, and costs. Although such risks as altered sensory nerve function and weakening of the mandibular body are associated with the LIAN procedure, it is a viable alternative to various regenerative techniques to rehabilitate a patient with an implant-supported fixed prosthesis.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Humanos , Implantación Dental Endoósea/métodos , Mandíbula/cirugía , Mandíbula/patología , Nervio Mandibular/cirugía , Atrofia/patología
13.
Int J Implant Dent ; 10(1): 11, 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38472687

RESUMEN

OBJECTIVE: This study analyzed and compared the biomechanical properties of maxillary sinus floor mucosa with implants at three different maxillary sinus angles during a modified internal sinus floor elevation procedure. METHODS: 3D reconstruction of the implant, maxillary sinus bone, and membrane were performed. The maxillary sinus model was set at three different angles. Two internal maxillary sinus elevation models were established, and finite element analysis was used to simulate the modified maxillary sinus elevation process. The implant was elevated to 10 mm at three maxillary sinus angles when the maxillary sinus floor membrane was separated by 0 and 4 mm. The stress of the maxillary sinus floor membrane was analyzed and compared. RESULTS: When the maxillary sinus floor membrane was separated by 0 mm and elevated to 10 mm, the peak stress values of the implant on the maxillary sinus floor membrane at three different angles were as follows: maxillary sinus I: 5.14-78.32 MPa; maxillary sinus II: 2.81-73.89 MPa; and maxillary sinus III: 2.82-51.87 MPa. When the maxillary sinus floor membrane was separated by 4 mm and elevated to 10 mm, the corresponding values were as follows: maxillary sinus I: 0.50-7.25 MPa; maxillary sinus II: 0.81-16.55 MPa; and maxillary sinus III: 0.49-22.74 MPa. CONCLUSION: The risk of sinus floor membrane rupture is greatly reduced after adequate dissection of the maxillary sinus floor membrane when performing modified internal sinus elevation in a narrow maxillary sinus. In a wide maxillary sinus, the risk of rupture or perforation of the wider maxillary sinus floor is reduced, regardless of whether traditional or modified internal sinus elevation is performed at the same height.


Asunto(s)
Implantes Dentales , Elevación del Piso del Seno Maxilar , Implantación Dental Endoósea/métodos , Elevación del Piso del Seno Maxilar/métodos , Seno Maxilar/cirugía , Membranas/cirugía
14.
Clin Exp Dent Res ; 10(2): e878, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38506282

RESUMEN

OBJECTIVES: Guided implant systems can be used as a training approach for placing implants. This in vitro prospective randomized pilot study evaluated the learning progression and skill development in freehand placement of two implants supporting a three-unit fixed prosthesis on a simulation model among novice operators. MATERIAL AND METHODS: Four senior dental students with no prior implant placement experience participated in the study. As a baseline, each student placed two mandibular and two maxillary implants by freehand technique on a simulation model. Sixteen consecutive guided placements using a static guide, dynamic navigation, and template-based guide followed totaling 32 guided implant placements into maxillary and mandibular models. Freehand implant placements before and after the various guided navigation attempts were compared to assess their impact on freehand skill. Metrics compared included surgical time, horizontal, vertical, and angulation discrepancies between the planned and placed implant positions measured on superimposed CBCT scans and analyzed with repeated measures regression with Tukey's adjusted pairwise comparisons (α = .05). RESULTS: Before training with guided techniques, the average baseline freehand implant placement took 10.2 min and decreased to 8.2 after training but this difference was not statistically significant (p = .1670) There was marginal evidence of a significant difference in the 3D apex deviation with an average improvement of 0.89 mm (95% CI: -0.38, 2.16, p = .1120); and marginal evidence of a significant improvement in the overall angle with an average improvement of 3.74° (95% CI: -1.00, 8.48, p = .0869) between baseline and final freehand placement attempts. CONCLUSIONS: Within the limitations of this pilot study, guided implant placement experiences did not significantly benefit or hinder freehand placement skills. Dental students should be exposed to various placement techniques to prepare them for clinical practice and allow them to make informed decisions on the best technique based on their skills and a given clinical scenario.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Humanos , Proyectos Piloto , Estudios Prospectivos , Implantación Dental Endoósea/métodos
15.
Braz Dent J ; 35: e245632, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537016

RESUMEN

This split-mouth randomized controlled trial aimed to evaluate the primary and secondary stability of hybrid implants with different thread configurations and hydrophilic surfaces. Twenty patients with a partially edentulous maxilla were selected. These patients received two types of implants with the same hydrophilic surface: CTP group: Cylindrical-Tapered implant with perforating threads; CTH: Cylindrical-Tapered implant with hybrid threads configuration (perforating and condensing threads). The primary and secondary stability parameters were measured by insertion torque and resonance frequency analysis at the time of implant placement and 7, 28, 56, and 90 days after the surgical procedure. The paired t-test was used to compare the data on the implant's stability between the groups. The statistical analysis was performed with a confidence level set at 95%. It was found that the implants in the CTH group presented higher primary stability values ​​at the time of implant placement, due to the higher ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) and insertion torque (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), than the implants in the CTP group. The CTH group presented higher ISQ values ​​in all follow-up periods: 7 days (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 days (68.61 ± 5.98 vs. 47.90 ±13.10), 56 days (74.09 ± 3.96 vs. 55.85 ± 13.18), and 90 days (75.45 ± 4.02 vs. 63.47 ± 6.92) after implant placement. Hybrid implants with perforating and condensing threads demonstrated greater stability than hybrid implants with only perforating threads.


Asunto(s)
Implantes Dentales , Humanos , Diseño de Prótesis Dental , Boca , Cara , Torque , Implantación Dental Endoósea/métodos
16.
BMC Oral Health ; 24(1): 393, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38539122

RESUMEN

BACKGROUND: The placement of implants into the alveolar socket right after tooth extraction is called immediate implant placement (IIP). This approach has its particularities depending on which region of the jaws is involved. The anterior mandible region is peculiar due to the presence of mandibular incisors, which have the shortest roots among all permanent teeth. PURPOSE: This study aimed to investigate the factors that could be associated with the risk of either cortical bone wall perforation or invasion of the 2 mm secure distance from the surrounding anatomical structures (defined as unsafe implant placement), with IIP in the maxillary aesthetic zone, in a cone-beam computed tomography (CBCT) virtual study. MATERIALS AND METHODS: CBCT exams from 239 eligible subjects were investigated. Implants were virtually placed in two distinct positions: prosthetically-driven (along the long axis of the existing tooth) and bone-driven position (according to the available bone and with regard to nearby anatomical structures). Correlation between several variables was tested, and binary logistic regression analysis in order to assess of the possible associations between covariates and unsafe placement was performed. RESULTS: Safe placing implants was significantly higher for the bone-driven in comparison to the prosthetically-driven position (22.2% vs. 3.3%, respectively), and the 2-mm secure distance from anatomical structures was not possible to respect in the majority of cases (77.6% vs. 82.9%, respectively). Covariates associated with a higher risk of unsafe placement were tooth region (CI in relation to IL and CA), decrease of labial concavity angle (LCA), decrease of mandible basal bone height (MBBH), and decrease in mandibular bone thickness at the tooth apex level (MBT0). CONCLUSION: The possibility of safely placing immediate implants in the anterior mandible is significantly higher for bone-driven than in prosthetically driven position. Presurgical virtual planning with CBCT is a great tool for minimizing the risk of implant unsafe placement with regards to the anatomical conditions in the mandible.


Asunto(s)
Implantes Dentales , Humanos , Implantación Dental Endoósea/métodos , Tomografía Computarizada de Haz Cónico/métodos , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Extracción Dental , Maxilar/cirugía
17.
Int J Implant Dent ; 10(1): 17, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38551730

RESUMEN

This case report provides a detailed description of a simple and fast bone regeneration procedure using a semi-customized three-dimensional ultra-fine titanium mesh. A 50-year-old male with a severe vertical and horizontal bone defect in the anterior mandible underwent implant treatment in a staged approach. The autologous bone was combined with a xenograft, and the mixture was grafted to augment the bone defect and covered with semi-customized ultra-fine titanium meshes, which were selected among its various types according to size and configuration of the bone defect, directly connected and immobilized on the tenting screws with minimal shaping. In a postoperative 6 months re-entry surgery, the performed titanium meshes were removed, implants were placed, and a bone core biopsy was obtained that demonstrated satisfactory new bone formation. Finally, two months later, the definitive prosthesis was installed. This semi-customized ultra-fine titanium mesh could help an implant clinician obtain more predictable results in the guided bone regeneration (GBR).


Asunto(s)
Aumento de la Cresta Alveolar , Implantes Dentales , Masculino , Humanos , Persona de Mediana Edad , Implantación Dental Endoósea/métodos , Titanio , Aumento de la Cresta Alveolar/métodos , Regeneración Ósea
18.
Quintessence Int ; 55(4): 314-326, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38502155

RESUMEN

OBJECTIVES: This case series aimed to assess the efficacy of a novel horizontal ridge augmentation modality using histology. Combinations of "sticky bone" and tenting screws without autologous bone were used as augmentative materials. METHOD AND MATERIALS: Five individuals presenting healed, atrophic, partially edentulous sites that required horizontal bone augmentation before implant placement were enrolled. Patients underwent the same augmentation type and 5 months of postoperative reentry procedures. The first surgery served as implant site development, whereas the biopsy and corresponding implant placement were performed during reentry. The bone was qualitatively analyzed using histology and histomorphometry and quantitatively evaluated using CBCT. RESULTS: Four individuals healed uneventfully. Early wound dehiscence occurred in one case. Histology showed favorable bone substitute incorporation into the newly formed bone and intimate contact between de novo bone and graft material in most cases. Histomorphometry revealed an average of 48 ± 28% newly formed bone, 19 ± 13% graft material, and 33 ± 26% soft tissue components. The CBCT-based mean alveolar ridge horizontal increase was 3.9 ± 0.6 mm at 5 months postoperatively. CONCLUSIONS: The described augmentation method appears suitable for implant site development resulting in favorable bone quality according to histology. However, clinicians must accommodate 1 to 2 mm of resorption in augmentative material width at the buccal aspect.


Asunto(s)
Aumento de la Cresta Alveolar , Sustitutos de Huesos , Tomografía Computarizada de Haz Cónico , Humanos , Aumento de la Cresta Alveolar/métodos , Femenino , Masculino , Persona de Mediana Edad , Sustitutos de Huesos/uso terapéutico , Implantación Dental Endoósea/métodos , Resultado del Tratamiento , Arcada Parcialmente Edéntula , Adulto , Biopsia , Anciano , Tornillos Óseos
19.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(4): 383-388, 2024 Apr 09.
Artículo en Chino | MEDLINE | ID: mdl-38548596

RESUMEN

In patients with periodontitis, due to problems of periodontal tissue infection as well as soft and hard tissues defects, it may lead to implant infection, gingival papilla loss, soft tissue recession and poor coordination with adjacent teeth. For such patients, periodontal infection should be actively controlled before dental implant therapy. In consideration of insufficient soft and hard tissues, alveolar ridge preservation and soft tissue augmentation procedure can be used to preserve or increase soft and hard tissues as much as possible. Multi-disciplinary treatment is often needed for occlusion problems and coordination with adjacent tooth. Periodontal maintenance treatment of implants and natural teeth is also necessary after implant therapy. This paper discussed these risk factors and strategies for prevention and control, in order to provide some clinical guidances for the implant treatment of periodontitis patients.


Asunto(s)
Pérdida de Hueso Alveolar , Aumento de la Cresta Alveolar , Implantes Dentales , Periodontitis , Diente , Humanos , Implantes Dentales/efectos adversos , Aumento de la Cresta Alveolar/efectos adversos , Aumento de la Cresta Alveolar/métodos , Periodontitis/complicaciones , Periodontitis/terapia , Factores de Riesgo , Implantación Dental Endoósea/métodos , Pérdida de Hueso Alveolar/etiología
20.
Clin Oral Investig ; 28(4): 226, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38514518

RESUMEN

OBJECTIVES: This retrospective cohort study aimed to identify the complications and risk factors associated with alveolar grafting using autologous mandibular ramus grafts, guided by the research question: What are the complications encountered in patients undergoing alveolar bone grafting using autologous mandibular ramus block and what are the risk factors associated with the development of these complications? MATERIALS AND METHODS: The study included 70 patients who underwent alveolar crest augmentation with autologous mandibular ramus block grafting. Intraoperative, early postoperative, and late postoperative complications were analyzed, as were various risk factors. RESULTS: The results showed that the majority of patients had successful outcomes with minimal complications. Sex was found to significantly influence the visibility of the inferior alveolar nerve (IAN). Early postoperative complications were associated with IAN visibility and the use of a single screw for graft fixation. Late postoperative complications were significantly associated with the presence of infection. CONCLUSION: The findings emphasize the importance of careful surgical techniques, infection prevention, and patient selection in minimizing complications. CLINICAL RELEVANCE: This article may contribute to clinicians' and so patients' understanding of potential risk factors associated with over all ramus block grafting procedure. Based on this information, clinicians can also improve their ability to manage risk factors and associated complications and compare ramus block grafting with other alternatives to determine the best treatment approach for that particular patient.


Asunto(s)
Aumento de la Cresta Alveolar , Implantación Dental Endoósea , Humanos , Implantación Dental Endoósea/métodos , Estudios Retrospectivos , Trasplante Óseo/métodos , Mandíbula/cirugía , Complicaciones Posoperatorias/epidemiología , Aumento de la Cresta Alveolar/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...